Automatic Test Equipment
Load Banks
HP-LBK High Precision
AISI316 high quality resistances and thanks to stability of our systems permit endurance test on UPS, GENERATORS, TURBINES and ENERGY STORAGE SYSTEMS, in accord to the strictest quality standards
Thanks to high quality of these products and wide range of powers Genstart International confirms itself the first in Europe
AC modular Systems
Resistive and inductive with 1 kVA resolution and working voltage from 115Vac up to 690Vac, 50-60Hz, and power up to 3.300kVA with 0,8 cosphy
AC systems 10 feet in container
Resistive and inductive with 1 kVA resolution and working voltage from 115Vac up to 690Vac, 50-60Hz, and power up to 3.300kVA with 0,8 cosphy
AC systems 20 feet in container
Resistive and inductive with 1 kVA resolution and working voltage from 115Vac up to 690Vac, 50-60Hz, and power up to 3.300kVA with 0,8 cosphy
Resistive Load
It’s the part that allows using programmable steps to simulate a real resistive load, keeping the current in phase to the voltage (Cosphy 1), always guaranteeing extreme precision based on the power used
Inductive Load
It is the part that allows using programmable steps to simulate a real inductive load, keeping the current lagging to the voltage (Cosphy different from 1), the inductive component combined with the resistive one creates a load with Cosphy variable between 0.2 and 0, 98, always guaranteeing extreme precision based on the power used
Capacitive Load
It’s the part that allows using programmable steps to simulate a real capacitive load, keeping the current in advance of the voltage (Cosphy different from 1), the capacitive component combined with the resistive one creates a load with Cosphy variable between 0.2 and 0, 98, always guaranteeing extreme precision based on the power used
Inductive and Resistive Load
For electronic generators such as inverters, a high peak current, which can generate a reactance in the magnetization, is not tolerated.
The solution is to create resistive and inductive loads with “predetermined cosfì”, 0.9 or 0.8, so that the magnetization peak doesn’t exceed 10/20% of the rated current
Distorting load
It is the part that allows using programmable steps to simulate a real distorting load, by inserting an Alternate resistive component (AC) a Distorting component (DC), it is possible to test and choose the size of the Generator most suitable for the type of installation
Standard voltage 400volt 50Hz
It’s possible to realize these systems with different dimensions and voltages
Contact us for more information about our products
Provide your name, email or phone number and the reason for your request. We will contact you as soon as possible.